Skip to content
Model Y

EPASTS_a062 — Am Phase Bridge Check

Full alert identifier: EPASTS_a062_amPhaseBridgeCheck

Alert description

This alert is reported by the ActuatorManager_R12 (AM) component when PWM pattern check failed, probably bridge FET or GDU failure.

Potential impact

EPAS full loss of assist.

Set condition

EPAS ECU actuator monitor detected failure (PWM phases).

Clear condition

EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.

Signals to check

These diagnostic fields are associated with EPASTS_a062. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTS_a062_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTS_a062.

Browse all EPASTS alert codes