Skip to content
Model Y

EPASTP_a256 — Dcvm Over Volt

Full alert identifier: EPASTP_a256_dcvmOverVolt

Alert description

This alert is reported by the DCVoltageMonitor_T222 (DCVM) component when overVoltage is detected.

Potential impact

Assist is disabled.

Set condition

EPAS has detected supply overvoltage (higher than 18v [calibratable]).

Clear condition

Perform EPAS ECU power cycle

Signals to check

These diagnostic fields are associated with EPASTP_a256. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a256_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a256.

Browse all EPASTP alert codes