EPASTP_a047 — Epm Vreg Volt Fail

Full alert identifier: EPASTP_a047_epmVregVoltFail

Alert description

This alert is reported by the ExternalPowerManager_A8140x (EPM) component when it detects VREG over and under voltage.

Potential impact

EPAS full loss of assist.

Set condition

EPAS ECU EPM device voltage monitoring failed (VREG over/under-voltage).

Clear condition

EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.

Signals to check

These diagnostic fields are associated with EPASTP_a047. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a047_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a047.