Skip to content
Model Y

EPASTP_a071 — Rsth Internal High Volt

Full alert identifier: EPASTP_a071_rsthInternalHighVolt

Alert description

This alert is reported by the HwResetHandler_TC3x (RSTH) component when there is an internal overvoltage detection. This diagnostic handles the overvoltage events reported by the PMS (Power Management System).

Potential impact

EPAS reset

Set condition

EPAS ECU power monitoring detected overvoltage.

Clear condition

EPAS HW failure. EPAS power cycle N times and if persists, the gear needs to be changed.

Signals to check

These diagnostic fields are associated with EPASTP_a071. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a071_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a071.

Browse all EPASTP alert codes