Skip to content
Model Y

EPASTP_a030 — Rsth Clock Reset

Full alert identifier: EPASTP_a030_rsthClockReset

Alert description

This alert is reported by the HwResetHandler_TC3x (RSTH) component when the clock frequency is out of range or clock system failure.

Potential impact

EPAS full loss of assist.

Set condition

EPAS uC core detected internal clocking error (clock frequency is out of range or system failure).

Clear condition

Perform EPAS Software update at first, replace HW if the alert appears again.

Signals to check

These diagnostic fields are associated with EPASTP_a030. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a030_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a030.

Browse all EPASTP alert codes