EPASTP_a096 — Rpp Rps Single Static Fail
Full alert identifier: EPASTP_a096_rppRpsSingleStaticFail
Alert description
This alert is reported by the RotorPositionProvider_R12 (RPP) component when there is 1 RPS sensor failure.
Potential impact
One rotor position sensor failed but EPAS still can operate normal.
Set condition
EPAS application diagnostics of rotor position sensor detected failure (single sensor).
Clear condition
Rotor position sensor QoS is QOS_RPS_NOMINAL_FAULT_TOLERANT for one full motor turn.
Signals to check
These diagnostic fields are associated with EPASTP_a096. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Debug Info
EPASTP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a096.