Skip to content
Model Y

EPASTP_a096 — Rpp Rps Single Static Fail

Full alert identifier: EPASTP_a096_rppRpsSingleStaticFail

Alert description

This alert is reported by the RotorPositionProvider_R12 (RPP) component when there is 1 RPS sensor failure.

Potential impact

One rotor position sensor failed but EPAS still can operate normal.

Set condition

EPAS application diagnostics of rotor position sensor detected failure (single sensor).

Clear condition

Rotor position sensor QoS is QOS_RPS_NOMINAL_FAULT_TOLERANT for one full motor turn.

Signals to check

These diagnostic fields are associated with EPASTP_a096. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Debug Info EPASTP_a096_debugInfo —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPASTP_a096.

Browse all EPASTP alert codes