Skip to content

DPB_a109 — GTM Tbu Mon Error

Full alert identifier: DPB_a109_GTMTbuMonError

Alert description

GTM reference frequency error.

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

Clock signal to GTM peripheral or system timer is faulty. The time passed in the sytem timer is compared with the time passed in GTM peripheral.

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a109.

Browse all DPB alert codes