Skip to content

DPB_a108 — GTM Ref Frequency Error

Full alert identifier: DPB_a108_GTMRefFrequencyError

Alert description

GTM reference frequency error.

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

GTM peripheral of micro controller is not right or reference clock from system ASIC (D_REF) is faulty or there is any fault in signal path from ASIC to micro controller. A 4kHz reference frequency signal from system ASIC is cyclically checked via GTM to be in correct range.

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a108.

Browse all DPB alert codes