Skip to content

VCRIGHT_a214 — Bridge Open Circuit Detect

Full alert identifier: VCRIGHT_a214_bridgeOpenCircuitDetect

Alert description

There is no current at the Right Vehicle Controller (VCRIGHT) through the bridge with the Left Vehicle Controller (VCLEFT).

Potential impact

LV bridge is open.

Set condition

No significant current is detected for 5s continuously between VCLEFT and VCRIGHT while VCRIGHT expects the bridge to be on.

Clear condition

Bridge open circuit detect protection resets if firmware turns the bridge off or if significant current through the bridge is observed continuously for 5s.

Signals to check

These diagnostic fields are associated with VCRIGHT_a214. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Current On Trip VCRIGHT_a214_currentOnTrip A
Threshold Current Absolute VCRIGHT_a214_thresholdCurrentAbsolute A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a214.

Browse all VCRIGHT alert codes