Skip to content

VCREAR_a242 — Hv Output Locked

Full alert identifier: VCREAR_a242_hvOutputLocked

Alert description

A request to change the HVC or Contactor power state has been denied.

Potential impact

High Voltage control or contactor may be faulted

Set condition

Electronic Parking Brake Right detects high voltage lockout request timed out after 0.5 seconds

Clear condition

Electronic Parking Brake Right unlocks high voltage output

Signals to check

These diagnostic fields are associated with VCREAR_a242. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cont Current State VCREAR_a242_contCurrentState —
Cont Desired State VCREAR_a242_contDesiredState —
Has Lockout Request VCREAR_a242_hasLockoutRequest —
High Current VCREAR_a242_highCurrent —
Hv State VCREAR_a242_hvState
0
DOWN
1
COMING UP
2
GOING DOWN
3
UP FOR DRIVE
4
UP FOR CHARGE
5
UP FOR DC CHARGE
6
UP
—
Hvc Current State VCREAR_a242_hvcCurrentState —
Hvc Desired State VCREAR_a242_hvcDesiredState —
Monitor Data Good VCREAR_a242_monitorDataGood —
Show 1 more field
Signal Unit
Vehicle Power State VCREAR_a242_vehiclePowerState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCREAR_a242.

Browse all VCREAR alert codes