VCREAR_a102 — HVBATTCON MIA
Full alert identifier: VCREAR_a102_HVBATTCON_MIA
Alert description
One or more of the messages the vehicle controller receives periodically from the High Voltage Battery Management System Controller (HVBATTCON) is not received, indicating the HVBATTCON may be unavailable (MIA).
Potential impact
Vehicle functions that depend on the HVBATTCON may be unavailable or may not function as expected.
Set condition
The vehicle controller does not receive one or more of the expected messages from the HVBATTCON within the expected time frame.
Clear condition
The vehicle controller receives the expected messages from the HVBATTCON.
Signals to check
These diagnostic fields are associated with VCREAR_a102. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
EGGREARPRIV Bmb Thermistor Min Max
VCREAR_
|
— |
EGGREARPRIV Network Management
VCREAR_
|
— |
EGGREARPRIV Soc Status
VCREAR_
|
— |
EGGREARPRIV Status
VCREAR_
|
— |
LOOP Charge Info
VCREAR_
|
— |
LOOP Energy Status
VCREAR_
|
— |
LOOP Grid Form Info
VCREAR_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCREAR_a102.