Skip to content

VCREAR_a241 — Di Output Locked

Full alert identifier: VCREAR_a241_diOutputLocked

Alert description

A request to change the DI power state has been denied.

Potential impact

Drive inverter may be faulted

Set condition

Electronic Parking Brake Left detects drive inverter lockout request timed out after 0.5 seconds

Clear condition

Electronic Parking Brake Left unlocks drive inverter output

Signals to check

These diagnostic fields are associated with VCREAR_a241. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Current State VCREAR_a241_currentState —
Desired State VCREAR_a241_desiredState —
Di Keep Alive VCREAR_a241_diKeepAlive —
Epb Sys Status VCREAR_a241_epbSysStatus —
Has Lockout Request VCREAR_a241_hasLockoutRequest —
High Current VCREAR_a241_highCurrent —
Monitor Data Good VCREAR_a241_monitorDataGood —
Vehicle Power State VCREAR_a241_vehiclePowerState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCREAR_a241.

Browse all VCREAR alert codes