VCLEFT_a598 — LVBMB eFuse Self Test Failed
Full alert identifier: VCLEFT_a598_LVBMBeFuseSelfTestFailed
Alert description
The vehicle controller detects the low voltage (LV) battery internal protection transistor (MOSFET) self test has failed, indicating one or more conditions affecting MOSFET functionality.
Potential impact
LV battery internal protection transistor (MOSFET) functionality is not confirmed. The LV battery may be unable to support vehicle electrical systems or to recharge via the power conversion system (PCS).
Set condition
Any part of the LV battery internal protection transistor (MOSFET) self test reports a failure. Alert log signal data should provide more information.
Clear condition
The LV battery internal protection transistor (MOSFET) self test passes. After a failed MOSFET self test, this typically requires LV battery replacement.
Signals to check
These diagnostic fields are associated with VCLEFT_a598. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
IBS Current
VCLEFT_
|
A |
LVBMS Pack Current
VCLEFT_
|
A |
Closed Chg IBS Current Count
VCLEFT_
|
— |
Closed Chg Pack Current Count
VCLEFT_
|
— |
Closed Chg Result
VCLEFT_
|
— |
Closed D Chg IBS Current Count
VCLEFT_
|
— |
Closed D Chg Pack Current Count
VCLEFT_
|
— |
Closed D Chg Result
VCLEFT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a598.