Skip to content

VCLEFT_a597 — LVBMB eFuse Self Test Not Ready

Full alert identifier: VCLEFT_a597_LVBMBeFuseSelfTestNotReady

Alert description

The low voltage (LV) battery internal protection transistor (MOSFET) self test has not yet completed.

Potential impact

Vehicle is unable to shift out of Park (P) until the LV battery internal protection transistor (MOSFET) self test completes or times out without completing. If the self test cannot complete and confirm LV battery MOSFET functionality, the LV battery may be unable to support vehicle electrical systems or to recharge via the power conversion system (PCS).

Set condition

The LV battery internal protection transistor (MOSFET) self test has not yet completed, potentially because a condition or combination of conditions prevents it from running. Alert log signal data should provide more information.

Clear condition

The LV battery internal protection transistor (MOSFET) self test completes, or times out after 35 seconds when the vehicle is in DRIVE power state.

Signals to check

These diagnostic fields are associated with VCLEFT_a597. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
EPB Released VCLEFT_a597_EPBReleased —
IBS Current Invalid VCLEFT_a597_IBSCurrentInvalid —
LVBMB Current Invalid VCLEFT_a597_LVBMB_currentInvalid —
LVBMB E Fuse Open VCLEFT_a597_LVBMB_eFuseOpen —
LV Bus Voltage Not Controllable VCLEFT_a597_LVBusVoltageNotControllable —
LV Not Being Supported VCLEFT_a597_LVNotBeingSupported —
Closed Chg Result VCLEFT_a597_closedChgResult
0
INVALID
1
FAILED
2
PASSED
—
Closed D Chg Result VCLEFT_a597_closedDChgResult
0
INVALID
1
FAILED
2
PASSED
—
Show 5 more fields
Signal Unit
External Power Supply VCLEFT_a597_externalPowerSupply —
Lost LV Bus Control VCLEFT_a597_lostLVBusControl —
Lv Battery Low Charge VCLEFT_a597_lvBatteryLowCharge —
Self Test State VCLEFT_a597_selfTestState
0
INACTIVE
1
CLOSED DISCHARGE
2
CLOSED CHARGE
—
Vehicle Is Updating VCLEFT_a597_vehicleIsUpdating —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a597.

Browse all VCLEFT alert codes