VCLEFT_a414 — Undervoltage Self Test Failure

Full alert identifier: VCLEFT_a414_undervoltageSelfTestFailure

Alert description

The Left Domain Undervoltage self-test did not pass, as a condition affecting a load on the Left Domain was detected during the self-test.

Potential impact

The undervoltage protection circuit may not be functional.

Set condition

The Left Domain Undervoltage self-test does not succeed. If a stuck-on or stuck-off condition is present, specific information can be found in the undervoltage self-test stuck-on or stuck-off debugging alerts.

Clear condition

Vehicle controller reset or successful Left Domain Undervoltage self-test.

Signals to check

These diagnostic fields are associated with VCLEFT_a414. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bridge Shutdown Active VCLEFT_a414_bridgeShutdownActive —
Device Stuck On Failure VCLEFT_a414_deviceStuckOnFailure —
Failure Reason VCLEFT_a414_failureReason
0
NONE
1
DEVICE STUCK ON
2
BRIDGE
3
BRIDGE AND DEVICE STUCK ON
4
LOAD UNATTEMPTED ON
8
FOLLOWER
16
TIMEOUT
—
Follower Egg Left VC Self Test Failure VCLEFT_a414_followerEggLeftVCSelfTestFailure —
Load Unattempted On Failure VCLEFT_a414_loadUnattemptedOnFailure —
Uv Loadshed Vsense Dig In VCLEFT_a414_uvLoadshedVsenseDigIn —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a414.

Browse all VCLEFT alert codes