VCLEFT_a577 — Bsi Hardware Issue

Full alert identifier: VCLEFT_a577_bsiHardwareIssue

Alert description

A condition affecting the blind spot indicator light has been detected. The indicator light may be unavailable or may not function as expected.

Potential impact

The blind spot indicator light may be unavailable or may not function as expected.

Set condition

The blind spot indicator light is disconnected, shorted to GND, voltage feedback when illuminated is not within the expected threshold, or the eFuse is tripped.

Clear condition

The blind spot indicator light is connected, voltage feedback when illuminated is within 2V - 4V, and the eFuse is not tripped.

Signals to check

These diagnostic fields are associated with VCLEFT_a577. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Current Sense Faulted VCLEFT_a577_currentSenseFaulted —
Output Faulted VCLEFT_a577_outputFaulted —
Over Current VCLEFT_a577_overCurrent —
Over Temperature VCLEFT_a577_overTemperature —
Temp Sense Faulted VCLEFT_a577_tempSenseFaulted —
Under Current VCLEFT_a577_underCurrent —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a577.