VCLEFT_a512 — LVBMS Fault MOS Open hardware OC
Full alert identifier: VCLEFT_a512_LVBMSFault_MOS_Open_hardwareOC
Alert description
The low voltage battery management system (LVBMS) reports it has opened the low voltage (LV) battery internal protection transistor (MOSFET) after detecting a hardware overcurrent condition.
Potential impact
The LV battery may be damaged and may be unable to support vehicle electrical systems.
Set condition
The LVBMS detects a hardware overcurrent condition affecting the LV battery.
Clear condition
The LVBMS reports the overcurrent condition is resolved and internal protection transistor (MOSFET) has been requested closed again.
Signals to check
These diagnostic fields are associated with VCLEFT_a512. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Frunk Open
VCLEFT_
|
— |
Overcurrent Direction
VCLEFT_
|
— |
Pack Temperature
VCLEFT_
|
C |
Pack Voltage Interval Max
VCLEFT_
|
V |
Pack Voltage Interval Min
VCLEFT_
|
V |
Service Mode
VCLEFT_
|
— |
Sum Cell Voltage
VCLEFT_
|
V |
Vehicle Power State
VCLEFT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a512.