VCLEFT_a515 — LVBMS Fault MOS Open cell OV

Full alert identifier: VCLEFT_a515_LVBMSFault_MOS_Open_cellOV

Alert description

The low voltage battery management system (LVBMS) reports it has opened the low voltage (LV) battery internal protection transistor (MOSFET) after detecting a cell overvoltage condition.

Potential impact

The LV battery may be damaged and may be unable to support vehicle electrical systems.

Set condition

The LVBMS detects a cell overvoltage condition affecting the LV battery.

Clear condition

The LVBMS reports the cell overvoltage condition is resolved and internal protection transistor (MOSFET) has been requested closed again.

Signals to check

These diagnostic fields are associated with VCLEFT_a515. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cell 1 Voltage VCLEFT_a515_cell1Voltage V
Cell 2 Voltage VCLEFT_a515_cell2Voltage V
Cell 3 Voltage VCLEFT_a515_cell3Voltage V
Cell 4 Voltage VCLEFT_a515_cell4Voltage V
Frunk Open VCLEFT_a515_frunkOpen —
Pack SOC VCLEFT_a515_packSOC %
Pack Voltage VCLEFT_a515_packVoltage V
Service Mode VCLEFT_a515_serviceMode —
Show 1 more field
Signal Unit
Vehicle Power State VCLEFT_a515_vehiclePowerState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a515.

Browse all VCLEFT alert codes