VCLEFT_a518 — LVBMS Fault MOS Open pack OV

Full alert identifier: VCLEFT_a518_LVBMSFault_MOS_Open_packOV

Alert description

The low voltage battery management system (LVBMS) reports it has opened the low voltage (LV) battery internal protection transistor (MOSFET) after detecting a pack overvoltage condition.

Potential impact

The LV battery may be damaged and may be unable to support vehicle electrical systems.

Set condition

The LVBMS detects a pack overvoltage condition affecting the LV battery.

Clear condition

The LVBMS reports the pack overvoltage condition is resolved and internal protection transistor (MOSFET) has been requested closed again.

Signals to check

These diagnostic fields are associated with VCLEFT_a518. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
IBS Voltage VCLEFT_a518_IBSVoltage V
Frunk Open VCLEFT_a518_frunkOpen —
Output Voltage At PCS VCLEFT_a518_outputVoltageAtPCS V
Pack SOC VCLEFT_a518_packSOC %
Pack Voltage VCLEFT_a518_packVoltage V
Service Mode VCLEFT_a518_serviceMode —
Target PCS Voltage VCLEFT_a518_targetPCSVoltage V
Vehicle Power State VCLEFT_a518_vehiclePowerState
0