Skip to content

VCLEFT_a436 — T LVBMS Discharge Over Current

Full alert identifier: VCLEFT_a436_TLVBMS_DischargeOverCurrent

Alert description

LV System Discharge Over Current

Potential impact

BMS will exit the HV_UP state

Set condition

BMS_packCurrent is less than -BMS_maxDischargeCurrent by too much for too long

Clear condition

All contactor set states are not CLOSED

Signals to check

These diagnostic fields are associated with VCLEFT_a436. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Hvjb Current Limit VCLEFT_a436_hvjbCurrentLimit
-32768
SNA
A
Max Discharge Current Limit VCLEFT_a436_maxDischargeCurrentLimit
-32768
SNA
A
Net Pack Current VCLEFT_a436_netPackCurrent
-32768
SNA
A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a436.

Browse all VCLEFT alert codes