VCLEFT_a496 — LV Battery Exit Drive Warning

Full alert identifier: VCLEFT_a496_LVBatteryExitDriveWarning

Alert description

The low voltage (LV) battery is in a critical state and the vehicle controller is about to trigger a graceful exit from drive (also known as a graceful power-off, or GPO). At least one other alert should be present when the vehicle starts to exit drive / graceful power-off occurs.

Potential impact

The vehicle will exit drive within the next few minutes, with a separate alert present to indicate that condition, and the next drive cycle will be blocked.

Set condition

May set due to a condition or combination of conditions indicating the LV battery cannot support the vehicle, including: the LV battery internal protection transistor (MOSFET) is open, the reverse battery eFuse has tripped (is open), or the vehicle controller is actively shedding vehicle electrical loads to conserve energy for essential functions. Alert log signal data should provide more information.

Clear condition

No condition or combination of conditions is detected indicating the LV battery cannot support the vehicle, or the vehicle has already entered graceful power-off (GPO) and is actively exiting drive.

Signals to check

These diagnostic fields are associated with VCLEFT_a496. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
MOS State VCLEFT_a496_MOSState
0
OPEN
1
CLOSED
2
INVALID
3
SNA
—
Not Enough Power For Support VCLEFT_a496_NotEnoughPowerForSupport —
Pcs mia VCLEFT_a496_PCS_MIA —
Bms State VCLEFT_a496_bmsState —
Frunk Open VCLEFT_a496_frunkOpen —
Reverse Battery E Fuse Fault VCLEFT_a496_reverseBatteryEFuseFault —
Service Mode VCLEFT_a496_serviceMode —
Vehicle Load Shed Active VCLEFT_a496_vehicleLoadShedActive —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a496.

Browse all VCLEFT alert codes