VCLEFT_a199 — Discnctd LV Battery
Full alert identifier: VCLEFT_a199_discnctdLVBattery
Alert description
The low voltage (LV) battery is disconnected.
Potential impact
Loss of support from the low voltage (LV) battery, so the vehicle electrical system is only supported via the power conversion system (PCS). Lead acid only: Some vehicle features may be unavailable due to load shedding. There should be another alert present to indicate this.
Set condition
No current flow detected to / from the low voltage (LV) battery for an extended time period.
Clear condition
Current flow detected to / from the low voltage (LV) battery.
Signals to check
These diagnostic fields are associated with VCLEFT_a199. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
ECPA State
VCLEFT_
|
— |
Battery SM State
VCLEFT_
|
— |
Disconnected Battery Test Current
VCLEFT_
|
A |
Disconnected Battery Test Prev Voltage
VCLEFT_
|
V |
Disconnected Battery Test Voltage
VCLEFT_
|
V |
Factory Mode
VCLEFT_
|
— |
Frunk Open
VCLEFT_
|
— |
Service Mode
VCLEFT_
|
— |
Show 2 more fields
| Signal | Unit |
|---|---|
Transport Mode
VCLEFT_
|
— |
Vehicle Power State
VCLEFT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a199.