Skip to content

VCLEFT_a207 — Exit Drive Low LV Bus Voltage

Full alert identifier: VCLEFT_a207_exitDriveLowLVBusVoltage

Alert description

An issue with the low voltage (LV) electrical system requires the vehicle to come to a stop immediately. The vehicle should enter graceful power-off (GPO) to exit drive, and a separate alert should indicate that condition.

Potential impact

The vehicle will not enter drive. If the vehicle is driving, it will exit drive through graceful power-off (GPO) to come to a stop immediately. A separate alert should be present to indicate the GPO

Set condition

Lead acid: Low voltage (LV) battery voltage below threshold for 3 seconds (3s); transistor gating LV battery connection is open (no current flow); vehicle load shedding is active; or reverse battery transistor issue detected.

Clear condition

Low voltage (LV) battery voltage above threshold; transistor gating LV battery connection is closed; no reverse battery transistor issue detected; vehicle loadshedding is not active.

Signals to check

These diagnostic fields are associated with VCLEFT_a207. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
ECPA State VCLEFT_a207_ECPAState
0
OPEN
1
CLOSED
2
INVALID
3
SNA
—
IBS Voltage VCLEFT_a207_IBSVoltage V
LVBMS Current Target Valid VCLEFT_a207_LVBMSCurrentTargetValid —
Lvbmsmia VCLEFT_a207_LVBMSMIA —
LVBMS Voltage VCLEFT_a207_LVBMSVoltage V
LVBMS Voltage Target Valid VCLEFT_a207_LVBMSVoltageTargetValid —
MOS State VCLEFT_a207_MOSState
0
OPEN
1
CLOSED
2
INVALID
3
SNA
—
Not Enough Power For Support VCLEFT_a207_NotEnoughPowerForSupport —
Show 13 more fields
Signal Unit
Pcs mia VCLEFT_a207_PCS_MIA —
A 180 DCDC Not Supporting LV Bus VCLEFT_a207_a180_DCDCNotSupportingLVBus —
Bms State VCLEFT_a207_bmsState —
Exit Drive Warning Timer Expired VCLEFT_a207_exitDriveWarningTimerExpired —
Frunk Open VCLEFT_a207_frunkOpen —
Hv State VCLEFT_a207_hvState
0
DOWN
1
COMING UP
2
GOING DOWN
3
UP FOR DRIVE
4
UP FOR CHARGE
5
UP FOR DC CHARGE
6
UP
—
Reverse Battery E Fuse Fault VCLEFT_a207_reverseBatteryEFuseFault —
Service Mode VCLEFT_a207_serviceMode —
Vehicle Load Shed Active VCLEFT_a207_vehicleLoadShedActive —
Vehicle Load Shed Hv Fault Active VCLEFT_a207_vehicleLoadShedHvFaultActive —
Vehicle Load Shed Post Crash Active VCLEFT_a207_vehicleLoadShedPostCrashActive —
Vehicle Load Shed Stage VCLEFT_a207_vehicleLoadShedStage
0
IDLE OR UNDEFINED
1
1
2
2
3
3
—
Vehicle Power State VCLEFT_a207_vehiclePowerState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—