VCFRONT_a580 — Right Headlight eFuse Trip
Full alert identifier: VCFRONT_a580_rightHeadlightEFuseTrip
Alert description
The front vehicle controller (VCFRONT) detects an eFuse overcurrent event (or a trip) on the right headlight power feed.
Potential impact
The right headlight may be unavailable or may not function as expected.
Set condition
The VCFRONT detects an eFuse overcurrent event on the right headlight power feed.
Clear condition
The VCFRONT no longer detects an eFuse overcurrent event on the right headlight power feed after one of the following: (1) a sleep cycle is completed; (2) a reset is completed; (3) a successful attempt to repower the circuit.
Signals to check
These diagnostic fields are associated with VCFRONT_a580. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Right Headlight Current
VCFRONT_
|
A |
Right Headlight Remaining Retries
VCFRONT_
|
— |
Right Headlight Voltage
VCFRONT_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a580.