VCFRONT_a374 — Lcc Inlet Solenoid Fault
Full alert identifier: VCFRONT_a374_lccInletSolenoidFault
Alert description
The liquid cooled condenser inlet solenoid has encountered an electrical fault (short, disconnect or internal).
Potential impact
HVAC cabin, cooling and heating, and powertrain performance may be limited.
Set condition
The liquid cooled condenser inlet solenoid is consuming less than 0.2 Amps, or greater than 2.0 Amps, when active
Clear condition
The liquid cooled condenser inlet solenoid is consuming between 0.2 Amps and 2.0 Amps when active
Signals to check
These diagnostic fields are associated with VCFRONT_a374. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Lcc Inlet Solenoid I Sense
VCFRONT_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a374.