VCFRONT_a287 — Lcc Exv Fault

Full alert identifier: VCFRONT_a287_lccExvFault

Alert description

The liquid cooled condenser EXV's motor driver has reported a fault.

Potential impact

Cabin / powertrain cooling and heating performance may be limited.

Set condition

The EXV motor driver has reported a fault.

Clear condition

The EXV motor driver no longer reports a fault.

Signals to check

These diagnostic fields are associated with VCFRONT_a287. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Charge Pump Undervoltage VCFRONT_a287_chargePumpUndervoltage —
Driver Has Comm Error VCFRONT_a287_driverHasCommError —
Driver State VCFRONT_a287_driverState —
Driver Therm Shutdown VCFRONT_a287_driverThermShutdown —
Driver Therm Warn VCFRONT_a287_driverThermWarn —
Is Coil Open X VCFRONT_a287_isCoilOpenX —
Is Coil Open Y VCFRONT_a287_isCoilOpenY —
Is Coil Short XN Gnd VCFRONT_a287_isCoilShortXNGnd —
Show 8 more fields
Signal Unit
Is Coil Short XN Vbb VCFRONT_a287_isCoilShortXNVbb —
Is Coil Short XP Gnd VCFRONT_a287_isCoilShortXPGnd —
Is Coil Short XP Vbb VCFRONT_a287_isCoilShortXPVbb —
Is Coil Short YN Gnd VCFRONT_a287_isCoilShortYNGnd —
Is Coil Short YN Vbb VCFRONT_a287_isCoilShortYNVbb —
Is Coil Short YP Gnd VCFRONT_a287_isCoilShortYPGnd —
Is Coil Short YP Vbb VCFRONT_a287_isCoilShortYPVbb —
Undervoltage VCFRONT_a287_undervoltage —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a287.