VCFRONT_a247 — Evap Solenoid Fault
Full alert identifier: VCFRONT_a247_evapSolenoidFault
Alert description
The refrigerant evaporator solenoid has encountered an electrical fault (short, disconnect or internal). HVAC cabin cooling (air conditioning) and powertrain performance may be limited.
Potential impact
HVAC cabin cooling (air conditioning) and powertrain cooling may be limited
Set condition
The refrigerant evaporator solenoid is consuming less than 0.2 Amps, or greater than 2.0 Amps, when active
Clear condition
The refrigerant evaporator solenoid is consuming between 0.2 Amps and 2.0 Amps when active
Signals to check
These diagnostic fields are associated with VCFRONT_a247. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Solenoid I Sense
VCFRONT_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a247.