VCFRONT_a333 — Vbat Fused Slow Trip OC

Full alert identifier: VCFRONT_a333_vbatFusedSlowTripOC

Alert description

The front vehicle controller fused high current circuit eFuse current average current value over the last second was > 60A.

Potential impact

The eFuse may have tripped.

Set condition

60A average eFuse current within last second.

Clear condition

Less than 60A eFuse current.

Signals to check

These diagnostic fields are associated with VCFRONT_a333. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Avg Current VCFRONT_a333_avgCurrent A
Max Current VCFRONT_a333_maxCurrent A
Vehicle State VCFRONT_a333_vehicleState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a333.