VCFRONT_a341 — Vbat Fused Fast Trip OC Max

Full alert identifier: VCFRONT_a341_vbatFusedFastTripOCMax

Alert description

The front vehicle controller fused high current circuit eFuse reported a current value over 100A within the last 10ms.

Potential impact

The eFuse may have tripped.

Set condition

100A eFuse current within last 10ms.

Clear condition

Less than 100A eFuse current.

Signals to check

These diagnostic fields are associated with VCFRONT_a341. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Avg Current VCFRONT_a341_avgCurrent A
Max Current VCFRONT_a341_maxCurrent A
Max Slope VCFRONT_a341_maxSlope A/ms
Vehicle State VCFRONT_a341_vehicleState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—