VCFRONT_a331 — iBooster Slow Trip OC
Full alert identifier: VCFRONT_a331_iboosterSlowTripOC
Alert description
The braking assist eFuse current average current value over the last second was > 25A.
Potential impact
The eFuse may have tripped.
Set condition
25A average eFuse current within last second.
Clear condition
Less than 25A eFuse current.
Signals to check
These diagnostic fields are associated with VCFRONT_a331. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Avg Current
VCFRONT_
|
A |
Max Current
VCFRONT_
|
A |
Vehicle State
VCFRONT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a331.