Skip to content

VCFRONT_a332 — Esp Slow Trip OC

Full alert identifier: VCFRONT_a332_espSlowTripOC

Alert description

The stability controller eFuse current average current value over the last second was > 40A.

Potential impact

The eFuse may have tripped.

Set condition

40A average eFuse current within last second.

Clear condition

Less than 40A eFuse current.

Signals to check

These diagnostic fields are associated with VCFRONT_a332. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Avg Current VCFRONT_a332_avgCurrent A
Max Current VCFRONT_a332_maxCurrent A
Vehicle State VCFRONT_a332_vehicleState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a332.