Skip to content

TAS_a172 — Damper Valve Rbnd RR

Full alert identifier: TAS_a172_damperValveRbndRR

Alert description

Rear right rebound damper valve detected to be unplugged, shorted, pin-swapped, or otherwise faulted.

Potential impact

All dampers will be unpowered.

Set condition

Rear right rebound damper valve detected to be unplugged, shorted, pin-swapped, or otherwise faulted.

Clear condition

Vehicle-power-state cycle from off to on.

Signals to check

These diagnostic fields are associated with TAS_a172. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Damper Valve Fault TAS_a172_damperValveFault —
Device On State Diagnostics TAS_a172_deviceOnStateDiagnostics —
Drv Device Fault TAS_a172_drvDeviceFault —
Drv Device Over Current TAS_a172_drvDeviceOverCurrent —
Drv Device Over Temperature TAS_a172_drvDeviceOverTemperature —
Drv Device Over Voltage TAS_a172_drvDeviceOverVoltage —
Drv Device Spi Comm Error TAS_a172_drvDeviceSpiCommError —
Drv Device Under Voltage TAS_a172_drvDeviceUnderVoltage —
Show 6 more fields
Signal Unit
Drv Failed Communication TAS_a172_drvFailedCommunication —
Drv Output Gnd Short TAS_a172_drvOutputGndShort —
Drv Output Open Circuit TAS_a172_drvOutputOpenCircuit —
Drv Output Over Current TAS_a172_drvOutputOverCurrent —
Drv Output Vm Short TAS_a172_drvOutputVmShort —
Drv Power On Reset TAS_a172_drvPowerOnReset —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TAS_a172.

Browse all TAS alert codes