Skip to content

TAS_a166 — Damper Valve Rbnd FL

Full alert identifier: TAS_a166_damperValveRbndFL

Alert description

Front left rebound damper valve detected to be unplugged, shorted, pin-swapped, or otherwise faulted.

Potential impact

All dampers will be unpowered.

Set condition

Front left rebound damper valve detected to be unplugged, shorted, pin-swapped, or otherwise faulted.

Clear condition

Vehicle-power-state cycle from off to on.

Signals to check

These diagnostic fields are associated with TAS_a166. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Damper Valve Fault TAS_a166_damperValveFault —
Device On State Diagnostics TAS_a166_deviceOnStateDiagnostics —
Drv Device Fault TAS_a166_drvDeviceFault —
Drv Device Over Current TAS_a166_drvDeviceOverCurrent —
Drv Device Over Temperature TAS_a166_drvDeviceOverTemperature —
Drv Device Over Voltage TAS_a166_drvDeviceOverVoltage —
Drv Device Spi Comm Error TAS_a166_drvDeviceSpiCommError —
Drv Device Under Voltage TAS_a166_drvDeviceUnderVoltage —
Show 6 more fields
Signal Unit
Drv Failed Communication TAS_a166_drvFailedCommunication —
Drv Output Gnd Short TAS_a166_drvOutputGndShort —
Drv Output Open Circuit TAS_a166_drvOutputOpenCircuit —
Drv Output Over Current TAS_a166_drvOutputOverCurrent —
Drv Output Vm Short TAS_a166_drvOutputVmShort —
Drv Power On Reset TAS_a166_drvPowerOnReset —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TAS_a166.

Browse all TAS alert codes