Skip to content

TAS_a170 — Damper Valve Rbnd RL

Full alert identifier: TAS_a170_damperValveRbndRL

Alert description

Rear left rebound damper valve detected to be unplugged, shorted, pin-swapped, or otherwise faulted.

Potential impact

All dampers will be unpowered.

Set condition

Rear left rebound damper valve detected to be unplugged, shorted, pin-swapped, or otherwise faulted.

Clear condition

Vehicle-power-state cycle from off to on.

Signals to check

These diagnostic fields are associated with TAS_a170. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Damper Valve Fault TAS_a170_damperValveFault —
Device On State Diagnostics TAS_a170_deviceOnStateDiagnostics —
Drv Device Fault TAS_a170_drvDeviceFault —
Drv Device Over Current TAS_a170_drvDeviceOverCurrent —
Drv Device Over Temperature TAS_a170_drvDeviceOverTemperature —
Drv Device Over Voltage TAS_a170_drvDeviceOverVoltage —
Drv Device Spi Comm Error TAS_a170_drvDeviceSpiCommError —
Drv Device Under Voltage TAS_a170_drvDeviceUnderVoltage —
Show 6 more fields
Signal Unit
Drv Failed Communication TAS_a170_drvFailedCommunication —
Drv Output Gnd Short TAS_a170_drvOutputGndShort —
Drv Output Open Circuit TAS_a170_drvOutputOpenCircuit —
Drv Output Over Current TAS_a170_drvOutputOverCurrent —
Drv Output Vm Short TAS_a170_drvOutputVmShort —
Drv Power On Reset TAS_a170_drvPowerOnReset —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TAS_a170.

Browse all TAS alert codes