SDCRER_a019 — Historical Fault Currents
Full alert identifier: SDCRER_a019_historicalFaultCurrents
Alert description
Secondary disconnect controller (SDC) detected abnormal electrical currents during a previous power-ON state. Data retrieved from electrically erasable programmable read-only memory (EEPROM).
Potential impact
Drive unit may not be functional due to previous electrical issue.
Set condition
SDC detected abnormal electrical currents when drive inverter (DI) was not switching as expected during a previous power cycle.
Clear condition
SDC completes successful power-ON self-test.
Signals to check
These diagnostic fields are associated with SDCRER_a019. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Avg Ia
SDCRER_
|
A |
Avg Ib
SDCRER_
|
A |
Fault Reason Fault Currents At Speed
SDCRER_
|
— |
Fault Reason Propagating 3 PS
SDCRER_
|
— |
Fault Reason Unmitigated UCR
SDCRER_
|
— |
Imbalance Seen
SDCRER_
|
— |
Max Abs Currents
SDCRER_
|
A |
Max Abs Elc Speed
SDCRER_
|
Hz |
Show 5 more fields
| Signal | Unit |
|---|---|
Phase Voltage Present
SDCRER_
|
— |
Speed From Voltage
SDCRER_
|
— |
Speed Was Valid
SDCRER_
|
— |
Transient Handling
SDCRER_
|
— |
Ucr Seen
SDCRER_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCRER_a019.