SDCRER_a015 — Phase V Irrational
Full alert identifier: SDCRER_a015_phaseVIrrational
Alert description
Secondary disconnect controller (SDC) phase voltage sensors are providing irrational values.
Potential impact
Pyro disconnect may not function as expected.
Set condition
At least one phase voltage measurement remains low while voltage should be constantly switching between low and high.
Clear condition
All phase voltage measurements are within rational / expected range.
Signals to check
These diagnostic fields are associated with SDCRER_a015. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Di Switching Pin
SDCRER_
|
— |
Reason V Phase Shorted High
SDCRER_
|
— |
Reason V Phase Shorted Low
SDCRER_
|
— |
V Bat
SDCRER_
|
V |
Va
SDCRER_
|
V |
Vb
SDCRER_
|
V |
Vc
SDCRER_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCRER_a015.