SDCRER_a015 — Phase V Irrational

Full alert identifier: SDCRER_a015_phaseVIrrational

Alert description

Secondary disconnect controller (SDC) phase voltage sensors are providing irrational values.

Potential impact

Pyro disconnect may not function as expected.

Set condition

At least one phase voltage measurement remains low while voltage should be constantly switching between low and high.

Clear condition

All phase voltage measurements are within rational / expected range.

Signals to check

These diagnostic fields are associated with SDCRER_a015. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Di Switching Pin SDCRER_a015_diSwitchingPin —
Reason V Phase Shorted High SDCRER_a015_reason_vPhaseShortedHigh —
Reason V Phase Shorted Low SDCRER_a015_reason_vPhaseShortedLow —
V Bat SDCRER_a015_vBat V
Va SDCRER_a015_va V
Vb SDCRER_a015_vb V
Vc SDCRER_a015_vc V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCRER_a015.