SDCRER_a014 — V Bus Irrational

Full alert identifier: SDCRER_a014_vBusIrrational

Alert description

Secondary disconnect controller (SDC) HV bus voltage sensor is providing irrational values.

Potential impact

Pyro disconnect may not function as expected.

Set condition

HV bus voltage measurement is low while HV backup rail is up.

Clear condition

HV bus voltage measurement is within rational / expected range.

Signals to check

These diagnostic fields are associated with SDCRER_a014. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
HV Backup Supply V SDCRER_a014_HVBackupSupplyV V
Boost Rail V SDCRER_a014_boostRailV V
Reason V Bus Shorted High SDCRER_a014_reason_vBusShortedHigh —
Reason V Bus Shorted Low SDCRER_a014_reason_vBusShortedLow —
V Bat SDCRER_a014_vBat V
Vbkup Good Fdbk SDCRER_a014_vbkupGoodFdbk —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCRER_a014.