SDCRER_a018 — Historical Pyro Trigger
Full alert identifier: SDCRER_a018_historicalPyroTrigger
Alert description
Secondary disconnect controller (SDC) triggered the 2-phase disconnect mechanism during a previous power ON state. Alert log signal data retrieved from electrically erasable programmable read-only memory (EEPROM) to be used for pyro disconnect trigger investigation afterward.
Potential impact
Drive unit may not be functional due to previous pyro disconnect.
Set condition
SDC reads alert log signal data from EEPROM for a previous pyro disconnect event.
Clear condition
SDC Power-ON self-test is successful.
Signals to check
These diagnostic fields are associated with SDCRER_a018. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
HV Backup Supply V
SDCRER_
|
V |
Boost Rail V
SDCRER_
|
V |
Di Uart MIA
SDCRER_
|
— |
Fault Currents Detected
SDCRER_
|
— |
Hv Power Good
SDCRER_
|
— |
Hv Power Not Good Qualified
SDCRER_
|
— |
Hvbkup P Good Pin
SDCRER_
|
— |
Max Abs Speed
SDCRER_
|
Hz |
Show 8 more fields
| Signal | Unit |
|---|---|
Pm Running Pin
SDCRER_
|
— |
Pyro Armed
SDCRER_
|
— |
Speed From Voltage
SDCRER_
|
— |
Speed Valid
SDCRER_
|
— |
Trigger Reason Fault Currents
SDCRER_
|
— |
Trigger Reason High Back EMF
SDCRER_
|
— |
Trigger Reason Hv Bad At Speed
SDCRER_
|
— |
V Bat
SDCRER_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCRER_a018.