SDCREL_a019 — Historical Fault Currents
Full alert identifier: SDCREL_a019_historicalFaultCurrents
Alert description
Secondary disconnect controller (SDC) detected abnormal electrical currents during a previous power-ON state. Data retrieved from electrically erasable programmable read-only memory (EEPROM).
Potential impact
Drive unit may not be functional due to previous electrical issue.
Set condition
SDC detected abnormal electrical currents when drive inverter (DI) was not switching as expected during a previous power cycle.
Clear condition
SDC completes successful power-ON self-test.
Signals to check
These diagnostic fields are associated with SDCREL_a019. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Avg Ia
SDCREL_
|
A |
Avg Ib
SDCREL_
|
A |
Fault Reason Fault Currents At Speed
SDCREL_
|
— |
Fault Reason Propagating 3 PS
SDCREL_
|
— |
Fault Reason Unmitigated UCR
SDCREL_
|
— |
Imbalance Seen
SDCREL_
|
— |
Max Abs Currents
SDCREL_
|
A |
Max Abs Elc Speed
SDCREL_
|
Hz |
Show 5 more fields
| Signal | Unit |
|---|---|
Phase Voltage Present
SDCREL_
|
— |
Speed From Voltage
SDCREL_
|
— |
Speed Was Valid
SDCREL_
|
— |
Transient Handling
SDCREL_
|
— |
Ucr Seen
SDCREL_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCREL_a019.