SDCREL_a019 — Historical Fault Currents

Full alert identifier: SDCREL_a019_historicalFaultCurrents

Alert description

Secondary disconnect controller (SDC) detected abnormal electrical currents during a previous power-ON state. Data retrieved from electrically erasable programmable read-only memory (EEPROM).

Potential impact

Drive unit may not be functional due to previous electrical issue.

Set condition

SDC detected abnormal electrical currents when drive inverter (DI) was not switching as expected during a previous power cycle.

Clear condition

SDC completes successful power-ON self-test.

Signals to check

These diagnostic fields are associated with SDCREL_a019. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Avg Ia SDCREL_a019_avgIa A
Avg Ib SDCREL_a019_avgIb A
Fault Reason Fault Currents At Speed SDCREL_a019_faultReason_faultCurrentsAtSpeed —
Fault Reason Propagating 3 PS SDCREL_a019_faultReason_propagating3PS —
Fault Reason Unmitigated UCR SDCREL_a019_faultReason_unmitigatedUCR —
Imbalance Seen SDCREL_a019_imbalanceSeen —
Max Abs Currents SDCREL_a019_maxAbsCurrents A
Max Abs Elc Speed SDCREL_a019_maxAbsElcSpeed Hz
Show 5 more fields
Signal Unit
Phase Voltage Present SDCREL_a019_phaseVoltagePresent —
Speed From Voltage SDCREL_a019_speedFromVoltage —
Speed Was Valid SDCREL_a019_speedWasValid —
Transient Handling SDCREL_a019_transientHandling
0
ALL SKIPPED
1
SKIPPED 3PS
2
3PS EARLY EXIT
3
3PS WAITED
—
Ucr Seen SDCREL_a019_ucrSeen —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCREL_a019.