SDCREL_a018 — Historical Pyro Trigger

Full alert identifier: SDCREL_a018_historicalPyroTrigger

Alert description

Secondary disconnect controller (SDC) triggered the 2-phase disconnect mechanism during a previous power ON state. Alert log signal data retrieved from electrically erasable programmable read-only memory (EEPROM) to be used for pyro disconnect trigger investigation afterward.

Potential impact

Drive unit may not be functional due to previous pyro disconnect.

Set condition

SDC reads alert log signal data from EEPROM for a previous pyro disconnect event.

Clear condition

SDC Power-ON self-test is successful.

Signals to check

These diagnostic fields are associated with SDCREL_a018. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
HV Backup Supply V SDCREL_a018_HVBackupSupplyV V
Boost Rail V SDCREL_a018_boostRailV V
Di Uart MIA SDCREL_a018_diUartMIA —
Fault Currents Detected SDCREL_a018_faultCurrentsDetected —
Hv Power Good SDCREL_a018_hvPowerGood —
Hv Power Not Good Qualified SDCREL_a018_hvPowerNotGoodQualified —
Hvbkup P Good Pin SDCREL_a018_hvbkupPGoodPin —
Max Abs Speed SDCREL_a018_maxAbsSpeed Hz
Show 8 more fields
Signal Unit
Pm Running Pin SDCREL_a018_pmRunningPin —
Pyro Armed SDCREL_a018_pyroArmed —
Speed From Voltage SDCREL_a018_speedFromVoltage —
Speed Valid SDCREL_a018_speedValid —
Trigger Reason Fault Currents SDCREL_a018_triggerReason_faultCurrents —
Trigger Reason High Back EMF SDCREL_a018_triggerReason_highBackEMF —
Trigger Reason Hv Bad At Speed SDCREL_a018_triggerReason_hvBadAtSpeed —
V Bat SDCREL_a018_vBat V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCREL_a018.