SDCREL_a018 — Historical Pyro Trigger
Full alert identifier: SDCREL_a018_historicalPyroTrigger
Alert description
Secondary disconnect controller (SDC) triggered the 2-phase disconnect mechanism during a previous power ON state. Alert log signal data retrieved from electrically erasable programmable read-only memory (EEPROM) to be used for pyro disconnect trigger investigation afterward.
Potential impact
Drive unit may not be functional due to previous pyro disconnect.
Set condition
SDC reads alert log signal data from EEPROM for a previous pyro disconnect event.
Clear condition
SDC Power-ON self-test is successful.
Signals to check
These diagnostic fields are associated with SDCREL_a018. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
HV Backup Supply V
SDCREL_
|
V |
Boost Rail V
SDCREL_
|
V |
Di Uart MIA
SDCREL_
|
— |
Fault Currents Detected
SDCREL_
|
— |
Hv Power Good
SDCREL_
|
— |
Hv Power Not Good Qualified
SDCREL_
|
— |
Hvbkup P Good Pin
SDCREL_
|
— |
Max Abs Speed
SDCREL_
|
Hz |
Show 8 more fields
| Signal | Unit |
|---|---|
Pm Running Pin
SDCREL_
|
— |
Pyro Armed
SDCREL_
|
— |
Speed From Voltage
SDCREL_
|
— |
Speed Valid
SDCREL_
|
— |
Trigger Reason Fault Currents
SDCREL_
|
— |
Trigger Reason High Back EMF
SDCREL_
|
— |
Trigger Reason Hv Bad At Speed
SDCREL_
|
— |
V Bat
SDCREL_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCREL_a018.