SDCREL_a007 — Fault Currents Detected
Full alert identifier: SDCREL_a007_faultCurrentsDetected
Alert description
Secondary disconnect controller (SDC) detected abnormal motor currents.
Potential impact
SDC may trigger the pyro disconnect.
Set condition
Detection of abnormal drive unit currents by the SDC when drive inverter (DI) is not switching.
Clear condition
Drive unit can control currents rationally, or SDC processor is reset.
Signals to check
These diagnostic fields are associated with SDCREL_a007. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Avg Ia
SDCREL_
|
A |
Avg Ib
SDCREL_
|
A |
Fault Reason Fault Currents At Speed
SDCREL_
|
— |
Fault Reason Propagating 3 PS
SDCREL_
|
— |
Fault Reason Unmitigated UCR
SDCREL_
|
— |
Imbalance Seen
SDCREL_
|
— |
Max Abs Currents
SDCREL_
|
A |
Max Abs Elc Speed
SDCREL_
|
Hz |
Show 5 more fields
| Signal | Unit |
|---|---|
Phase Voltage Present
SDCREL_
|
— |
Speed From Voltage
SDCREL_
|
— |
Speed Was Valid
SDCREL_
|
— |
Transient Handling
SDCREL_
|
— |
Ucr Seen
SDCREL_
|
— |
Check other alerts