Skip to content

SDCREL_a007 — Fault Currents Detected

Full alert identifier: SDCREL_a007_faultCurrentsDetected

Alert description

Secondary disconnect controller (SDC) detected abnormal motor currents.

Potential impact

SDC may trigger the pyro disconnect.

Set condition

Detection of abnormal drive unit currents by the SDC when drive inverter (DI) is not switching.

Clear condition

Drive unit can control currents rationally, or SDC processor is reset.

Signals to check

These diagnostic fields are associated with SDCREL_a007. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Avg Ia SDCREL_a007_avgIa A
Avg Ib SDCREL_a007_avgIb A
Fault Reason Fault Currents At Speed SDCREL_a007_faultReason_faultCurrentsAtSpeed —
Fault Reason Propagating 3 PS SDCREL_a007_faultReason_propagating3PS —
Fault Reason Unmitigated UCR SDCREL_a007_faultReason_unmitigatedUCR —
Imbalance Seen SDCREL_a007_imbalanceSeen —
Max Abs Currents SDCREL_a007_maxAbsCurrents A
Max Abs Elc Speed SDCREL_a007_maxAbsElcSpeed Hz
Show 5 more fields
Signal Unit
Phase Voltage Present SDCREL_a007_phaseVoltagePresent —
Speed From Voltage SDCREL_a007_speedFromVoltage —
Speed Was Valid SDCREL_a007_speedWasValid —
Transient Handling SDCREL_a007_transientHandling
0
ALL SKIPPED
1
SKIPPED 3PS
2
3PS EARLY EXIT
3
3PS WAITED
—
Ucr Seen SDCREL_a007_ucrSeen —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCREL_a007.

Browse all SDCREL alert codes