SDCF_a018 — Historical Pyro Trigger
Full alert identifier: SDCF_a018_historicalPyroTrigger
Alert description
Secondary disconnect controller (SDC) triggered the 2-phase disconnect mechanism during a previous power ON state. Alert log signal data retrieved from electrically erasable programmable read-only memory (EEPROM) to be used for pyro disconnect trigger investigation afterward.
Potential impact
Drive unit may not be functional due to previous pyro disconnect.
Set condition
SDC reads alert log signal data from EEPROM for a previous pyro disconnect event.
Clear condition
SDC Power-ON self-test is successful.
Signals to check
These diagnostic fields are associated with SDCF_a018. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
HV Backup Supply V
SDCF_
|
V |
Boost Rail V
SDCF_
|
V |
Di Uart MIA
SDCF_
|
— |
Fault Currents Detected
SDCF_
|
— |
Hv Power Good
SDCF_
|
— |
Hv Power Not Good Qualified
SDCF_
|
— |
Hvbkup P Good Pin
SDCF_
|
— |
Max Abs Speed
SDCF_
|
Hz |
Show 8 more fields
| Signal | Unit |
|---|---|
Pm Running Pin
SDCF_
|
— |
Pyro Armed
SDCF_
|
— |
Speed From Voltage
SDCF_
|
— |
Speed Valid
SDCF_
|
— |
Trigger Reason Fault Currents
SDCF_
|
— |
Trigger Reason High Back EMF
SDCF_
|
— |
Trigger Reason Hv Bad At Speed
SDCF_
|
— |
V Bat
SDCF_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCF_a018.