SDCF_a019 — Historical Fault Currents
Full alert identifier: SDCF_a019_historicalFaultCurrents
Alert description
Secondary disconnect controller (SDC) detected abnormal electrical currents during a previous power-ON state. Data retrieved from electrically erasable programmable read-only memory (EEPROM).
Potential impact
Drive unit may not be functional due to previous electrical issue.
Set condition
SDC detected abnormal electrical currents when drive inverter (DI) was not switching as expected during a previous power cycle.
Clear condition
SDC completes successful power-ON self-test.
Signals to check
These diagnostic fields are associated with SDCF_a019. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Avg Ia
SDCF_
|
A |
Avg Ib
SDCF_
|
A |
Fault Reason Fault Currents At Speed
SDCF_
|
— |
Fault Reason Propagating 3 PS
SDCF_
|
— |
Fault Reason Unmitigated UCR
SDCF_
|
— |
Imbalance Seen
SDCF_
|
— |
Max Abs Currents
SDCF_
|
A |
Max Abs Elc Speed
SDCF_
|
Hz |
Show 5 more fields
| Signal | Unit |
|---|---|
Phase Voltage Present
SDCF_
|
— |
Speed From Voltage
SDCF_
|
— |
Speed Was Valid
SDCF_
|
— |
Transient Handling
SDCF_
|
— |
Ucr Seen
SDCF_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCF_a019.