Skip to content

SDCF_a006 — Pyro Triggered

Full alert identifier: SDCF_a006_pyroTriggered

Alert description

Secondary disconnect controller (SDC) triggered the 2-phase disconnect mechanism.

Potential impact

Drive unit may be permanently disabled after 2-phase disconnect occurs.

Set condition

SDC detects abnormal electrical condition.

Clear condition

Clears on SDC processor reset.

Signals to check

These diagnostic fields are associated with SDCF_a006. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
HV Backup Supply V SDCF_a006_HVBackupSupplyV V
Boost Rail V SDCF_a006_boostRailV V
Di Uart MIA SDCF_a006_diUartMIA —
Fault Currents Detected SDCF_a006_faultCurrentsDetected —
Hv Power Good SDCF_a006_hvPowerGood —
Hv Power Not Good Qualified SDCF_a006_hvPowerNotGoodQualified —
Hvbkup P Good Pin SDCF_a006_hvbkupPGoodPin —
Max Abs Speed SDCF_a006_maxAbsSpeed Hz
Show 8 more fields
Signal Unit
Pm Running Pin SDCF_a006_pmRunningPin —
Pyro Armed SDCF_a006_pyroArmed —
Speed From Voltage SDCF_a006_speedFromVoltage —
Speed Valid SDCF_a006_speedValid —
Trigger Reason Fault Currents SDCF_a006_triggerReason_faultCurrents —
Trigger Reason High Back EMF SDCF_a006_triggerReason_highBackEMF —
Trigger Reason Hv Bad At Speed SDCF_a006_triggerReason_hvBadAtSpeed —
V Bat SDCF_a006_vBat V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SDCF_a006.

Browse all SDCF alert codes