Skip to content

RSA_a208 — Startup Sequence Failed2

Full alert identifier: RSA_a208_startupSequenceFailed2

Alert description

Power steering startup sequence is unsuccessful.

Potential impact

The motor is disqualified and system health is degraded.

Set condition

Controller calibration check is unsuccessful, corresponding controller monitor is not responding, or state timeout occurs.

Clear condition

Startup sequence passes. Startup sequence is run during vehicle startup, and the condition may resolve by drive cycling the vehicle.

Signals to check

These diagnostic fields are associated with RSA_a208. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bus Current RSA_a208_busCurrent amp
Phase A Current RSA_a208_phaseACurrent A
Phase B Current RSA_a208_phaseBCurrent A
Phase C Current RSA_a208_phaseCCurrent A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of RSA_a208.

Browse all RSA alert codes