Skip to content

PEPS_a149 — MAQ473 GQE Fault

Full alert identifier: PEPS_a149_MAQ473GQEFault

Alert description

The secondary motor position sensor has been deemed invalid.

Potential impact

The motor is disqualified and handwheel feedback health is degraded.

Set condition

The motor position sensor experiences an issue affecting configuration and/or communication, or magnetic flags are set.

Clear condition

The sensor configuration is successful, the angle reading is active and valid, and there are no magnetic flags set.

Signals to check

These diagnostic fields are associated with PEPS_a149. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Config Fault PEPS_a149_configFault —
Config State PEPS_a149_configState —
Mag H PEPS_a149_magH —
Mag L PEPS_a149_magL —
Mag LH Fault PEPS_a149_magLHFault —
Request Data PEPS_a149_requestData —
Response Data PEPS_a149_responseData —
Response Invalid PEPS_a149_responseInvalid —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PEPS_a149.

Browse all PEPS alert codes