Skip to content

PEPS_a130 — Gatedriver Fault

Full alert identifier: PEPS_a130_gatedriverFault

Alert description

The gate driver reported an electrical condition preventing operation.

Potential impact

The motor is disqualified and system health is degraded.

Set condition

The gate driver is reporting an electrical condition affecting its functionality.

Clear condition

All gate driver electrical issues have cleared. A stable power supply is necessary. A DRIVE or CONDITIONING cycle is necessary to recover.

Signals to check

These diagnostic fields are associated with PEPS_a130. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Logic Overvoltage PEPS_a130_LogicOvervoltage —
VB Bout Of Range PEPS_a130_VBBoutOfRange —
Vds Overvoltage PEPS_a130_VdsOvervoltage —
Vgs Undervoltage PEPS_a130_VgsUndervoltage —
Vio Undervoltage PEPS_a130_VioUndervoltage —
Vreg Out Of Range PEPS_a130_VregOutOfRange —
Bootstrap Undervoltage PEPS_a130_bootstrapUndervoltage —
Config Mismatch PEPS_a130_configMismatch —
Show 9 more fields
Signal Unit
Driver MIA PEPS_a130_driverMIA —
Eeprom Error PEPS_a130_eepromError —
Fault Pin PEPS_a130_faultPin —
Load Fault PEPS_a130_loadFault —
Overtemperature PEPS_a130_overtemperature —
Power On Reset PEPS_a130_powerOnReset —
Serial Error PEPS_a130_serialError —
Temperature Warning PEPS_a130_temperatureWarning —
Watch Dog Timeout PEPS_a130_watchDogTimeout —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PEPS_a130.

Browse all PEPS alert codes