PCS2_a088 — Chg Input V Drop High
Full alert identifier: PCS2_a088_chgInputVDropHigh
Alert description
During AC charging, the measured root mean squared (RMS) voltage across the lines has decreased below the voltage drop threshold when compared to the RMS voltage at the start of AC charging
Potential impact
Reduced AC charge rate
Set condition
The RMS voltage across the lines has decreased below the voltage drop threshold
Clear condition
The RMS voltage across the lines has no longer decreased below the voltage drop threshold
Signals to check
These diagnostic fields are associated with PCS2_a088. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Grid Config
PCS2_
|
— |
Lines Faulted
PCS2_
|
— |
Present Current Rms
PCS2_
|
A |
Present Voltage Rms
PCS2_
|
V |
Start Voltage Rms
PCS2_
|
V |
Under Voltage Rms Threshold
PCS2_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a088.