PCS2_a112 — Chg Input V Drop Too High
Full alert identifier: PCS2_a112_chgInputVDropTooHigh
Alert description
During the ac charging, the measured rms voltage across the lines has decreased below the high impedance detection RMS voltage threshold when compared to the RMS voltage at the start of AC charging
Potential impact
AC charging functionality may be limited or paused
Set condition
The root mean squared (RMS) voltage across the lines has decreased below the high impedance detection RMS voltage threshold
Clear condition
The root mean squared (RMS) voltage across the lines has no longer decreased below the expected RMS voltage threshold
Signals to check
These diagnostic fields are associated with PCS2_a112. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Lines Faulted
PCS2_
|
— |
Present Voltage Rms
PCS2_
|
V |
Start Voltage Rms
PCS2_
|
V |
Under Voltage Rms Threshold
PCS2_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a112.