PCS2_a063 — Chg Unknown Grid Config
Full alert identifier: PCS2_a063_chgUnknownGridConfig
Alert description
The Power Conversion System (PCS) detects an unknown grid configuration from the external charging equipment
Potential impact
AC charging functionality may be unavailable
Set condition
The PCS detects unknown grid configuration
Clear condition
The PCS stops being commanded to AC charge
Signals to check
These diagnostic fields are associated with PCS2_a063. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
L 1 L 2 Available For Charging
PCS2_
|
— |
L 1 L 3 Available For Charging
PCS2_
|
— |
L 1 N Available For Charging
PCS2_
|
— |
L 2 L 3 Available For Charging
PCS2_
|
— |
L 2 N Available For Charging
PCS2_
|
— |
L 3 N Available For Charging
PCS2_
|
— |
Phase Diff L 1 L 3 L 2 L 3
PCS2_
|
Deg |
Phase Diff L 1 N L 2 N
PCS2_
|
Deg |
Show 2 more fields
| Signal | Unit |
|---|---|
Phase Diff L 1 N L 3 N
PCS2_
|
Deg |
Phase Diff L 2 N L 3 N
PCS2_
|
Deg |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a063.